Morpheus Operation Manual236
MIDI SPECIFICATION
• Program Map Data
F0 SysEx Status Byte
18 E-mu Mfg. ID
0C Morpheus Product ID
dd Device ID 0-15
07 Command ID
bb Map Number, 0-3
ll ls byte of Program Number
mm ms byte of Program Number
... 128 total entries
F7 End of SysEx Status
• Master Settings Request
F0 SysEx Status Byte
18 E-mu Mfg. ID
0C Morpheus Product ID
dd Device ID 0-15
08 Command ID
F7 End of SysEx Status
• Master Settings Data
A master settings request responds with streams of parmnumber/
parmvalue pairs in running status mode. Two separate dumps are sent:
first global parms, then scratch midimap parms.
F0 SysEx Status Byte
18 E-mu Mfg. ID
0C Morpheus Product ID
dd Device ID 0-15
03 Command ID
pl lsb Parm Number
pm msb Parm Number
vl lsb Parm Value
vm msb Parm Value
... Global Parms